ANSINSPIResidential Inground Swimming Pools-This standard is a revision of ANSI/NSPI-5 , Standard for Residential Inground Swimming. Standards such as ANSI/AHAM RAC, Room Air For homes with inground pools, ANSI/NSPI , Residential Inground Swimming. For the design, equipment, and installation of residential inground swimming pools. This standard is referenced in the International Codes. PURCHASE .

Author: Zololkis Mauzilkree
Country: Namibia
Language: English (Spanish)
Genre: Software
Published (Last): 24 January 2012
Pages: 170
PDF File Size: 16.82 Mb
ePub File Size: 9.17 Mb
ISBN: 803-1-93741-139-9
Downloads: 72143
Price: Free* [*Free Regsitration Required]
Uploader: Tera

Already Subscribed to this document. The objective of this standard is to provide recommended minimum guidelines for the design, equipment, installation, and use of residential inground swimming pools.

ANSI/NSPI – Residential Inground Swimming Pools

Conclusions of Nsi The Florida Building Commission has the specific statutory authority to interpret the provisions of the Florida Building Code by entering a declaratory statement. An approved gravity drainage system. Hair and lint catchers shall be so designed that they can be easily dismantled for cleaning and inspection and shall be so located as to be easily accessible for cleaning.

Section AG – Abbreviations: No portion of an outdoor swimming pool, including appurtenant equipment, enclosing barrier and other structures as wnsi by this chapter, shall be located less than twenty five feet 25′ from any property line, or less than one hundred feet ‘ from any residence, existing at the time of construction of the pool, on any other property.

The maximum slope permitted between point D 2 and the transition point shall not exceed one unit vertical to three units horizontal 1: Pool filtration pump motors shall meet the following requirements: Spas or hot tubs with a safety cover which complies with ASTM F, as listed in section AG, shall be exempt from the provision of this appendix.

All appurtenant structures, installations and equipment, such as showers, dressing rooms, equipment houses or other buildings and structures, including plumbing, heating and air conditioning systems, shall comply with all applicable requirements of this code.

For the purposes of this combined or total measurement and the application of this section, any swimming pool shall be considered as having 4 sides, based upon the 4 most significant changes of direction. Findings of Fact 1.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. The Petitioner asks three questions regarding this project:.

STATE OF FLORIDA

Any swimming pool other than a private swimming pool. Disinfection equipment installed for anssi use of chlorine compounds shall have sufficient capacity to maintain a minimum free chlorine residual of five-tenths 0. Appendix G of the international one- and two-family dwelling code,is hereby adopted as part of this chapter in the following amended and restated form ans shall read as follows to the extent that said amended appendix G is inconsistent with the other provisions of this chapter, the more restrictive provisions shall govern and prevail: Where there are decorative cutouts within vertical members, spacing within the nspii shall not exceed 1.

  LT1083CP DATASHEET PDF

The energy requirements for portable spas shall be in accordance with Section Where the barrier is composed of diagonal members, such as a lattice fence, the maximum opening formed by the diagonal members shall not be more than 1. Barriers shall be located so as to prohibit permanent structures, equipment or similar objects from being used to climb the barriers.

A fence, a wall, a building wall, the wall of an aboveground swimming pool, or a combination thereof, which completely surrounds the swimming pool and obstructs access to the swimming pool. Where a permanently installed pool is installed at a dwelling unit sat least one GFCI protected one hundred twenty five volt receptacle shall be located a minimum of ten feet 10′ 3. In swimming pools thirty feet 30′ in width or less, water circulation system outlets shall be located so as to provide at least one outlet at the deepest point in the pool.

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. All discharged water shall be drained entirely upon the property on which the swimming pool is located and shall not flow on any adjoining property.

All swimming pools shall be provided with a recirculating skimming device or overflow gutters to remove scum and foreign matter from the surface of the water. A minimum horizontal or vertical distance of three 3 feet shall separate such outlets.

Swimming pool walls and floors shall be constructed of any impervious material ansl will provide a tight tank with white or light colored finish and easily cleaned surfaces.

Add to Alert PDF. It is also intended to assist local jurisdictions and other regulatory bodies, where necessary, in the development and promulgation of criteria for residential inground swimming pools.

Such deactivation shall last for not more than 15 seconds. The top of the barrier shall be at least nsp inches above grade measured on the side of the barrier which faces away from the swimming anssi. Recirculating systems shall contain rapid pressure filters. See definition of Private Swimming Pool. The Petitioner asks three questions regarding this project: Water drained from the pool shall not be discharged during periods of rain or storms.

  BYGGHANDLINGAR 90 DEL 8 PDF

ANSI/NSPI-5 2003 Standard for Residential Inground Swimming Pools (PDF Download)

Your Alert Profile lists the documents that will be monitored. Where the barrier is composed of horizontal and vertical members and the distance between the tops of nsi horizontal members is less than 45 inches 1, mmthe horizontal members shall be located on the swimming pool side of the barrier.

This definition includes inground, aboveground and onground swimming pools, hot tubs and spas.

The swimming pool and equipment shall be equipped to be emptied completely of water and the discharged water ansj be disposed of in an approved manner that will not create a nuisance. Unobstructed walk areas not less than thirty six inches 36″ wide shall be provided immediately adjacent to and extending entirely around the pool.

Subscription pricing is determined by: The alarm system shall be equipped with a manual means, such as touchpad or switch, to temporarily deactivate the alarm for a single opening. For the purpose of this section, the front line of any residence shall be a line drawn parallel to aansi road abutting the lot which intersects the point of the residence located closest to that road. Maximum velocity limits are: Pools shall be equipped with facilities for completely emptying the pool and the discharge of the pool water shall be nspo a rate not exceeding two hundred gallons per minute.

Where the top of the pool structure is above grade, such as a hot tub or spa, the barrier may be at ground level, such jspi the hot tub or spa, or mounted on top of the hot tub or spa.

The following words and znsi shall, for the purpose of this chapter and as used elsewhere in this code, have the meaning shown herein: Pool pump motors shall not nasi split-phase, shaded-pole or capacitor start-induction run types. If the makeup water is added directly to the pool, the outlet shall be at least six inches 6″ above the upper rim of the pool.

A minimum of one recirculation system inlet shall be provided for every six hundred fifteen square feet of surface area of the pool. Where provided, vacuum or pressure cleaner fitting s shall be located in an accessible position s at least six inches 6″ and not greater than twelve inches 12″ below the minimum operational water level or as an attachment to the skimmer s.